Table 2

Ultrasound B-scan versus anterior segment optical coherence tomography: image features

FeaturesUltrasound B scan
N=126
Number (%)
AS-OCT
N=126
Number (%)
Acoustic features
 Hollow38 (30.2)30 (23.8)
 Solid51 (40.5)86 (68.3)
 Lesion undetectable37 (29.4)10 (7.9)
Internal pattern
 Heterogeneous39 (31)29 (23.1)
 Homogeneous50 (39.7)87 (69)
 Lesion undetectable37 (29.4)10 (7.9)
VisibilityGoodFairUndetectableGoodFairUndetectable
 Anterior63 (50)25 (19.8)38 (30.2)112 (88.9)10 (7.9)4 (3.2)
 Medial57 (45.2)29 (23)40 (31.7)59 (46.8)44 (34.9)23 (18.3)
 Lateral51 (40.5)34 (27)41 (32.5)60 (47.6)43 (34.1)23 (18.3)
 Posterior54 (42.9)33 (26.2)39 (31)16 (12.7)57 (45.2)53 (42.1)
All margins seen
 Yes81 (64.3)59 (46.8)
 No45 (35.7)67 (53.2)
Posterior shadowing
 None121 (96)43 (34.1)
 Yes—trace2 (1.6)12 (9.5)
 Yes—mild1 (0.8)22 (17.5)
 Yes—moderate022 (17.5)
 Yes—severe2 (1.6)27 (21.4)
Elevation (mm)
 Mean (SD, range)1.8 (±1.4, 0.3 to 5.8)1.0 (±1.1, 0.1 to 6.0)
Longitudinal base (mm)
 Mean (SD, range)2.6 (±1.5, 1.0 to 7.8)2.8 (±1.6, 0.8 to 8.1)
Transverse base (mm)
 Mean (SD, range)2.9 (±0.8, 0.8 to 12.8)2.9 (±1.6, 0.7 to 7.6)
  • AS-OCT, anterior segment optical coherence tomography.